Ontario HRAI Members should be aware the IESO will be removing the CAC incentives for the SEER 14.5 & 15 (EER 12 & 12.5) from the program as of June 30, 2017 and will be introducing incentives for the following products starting July 1, 2017:
|
Eligible HVAC Measure |
Details/Description |
Incentive Amount |
|
High efficiency furnace equipped with a variable speed ECM |
Must replace an existing furnace (currently in the program ) |
$250.00 |
|
Drop in variable speed ECM for existing furnace |
Must replace existing PSC furnace motor |
$150.00 |
|
Circulator Pump Equipped with a variable speed ECM |
Must be installed on a hydronic heating system and not on a DHW heater |
$30.00 |
|
Energy Star certified CAC system18+ SEER |
Must be 18 SEER or higher and 13 EER or higher |
$600.00 |
|
Ductless ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – For electrically heated homes only |
$1000.00 |
|
Ductless Multiport ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – For electrically heated homes only |
$1250.00 for one exterior unit and the first two interior units, plus $250.00 for each additional interior unit attached to the same exterior unit up to a max. participant incentive of $3000.00 |
|
Ducted ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – For electrically heated homes only |
$1250.00 |
|
Cold Climate Ductless ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – Must meet NEEP’s Cold Climate Air Source Heat Pump Specification (NEEP, 2017 or more recent) and; – Have a COP at -15°C(5°F) greater than 2.0 at a max capacity operation and; – Maintain a max capacity at -15°C (5°F) that is greater than or equal to 55% of maximum capacity at 8.3°C (47°F) – For electrically heated homes only |
$1500.00 |
|
Cold Climate Ductless Multiport ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – Must meet NEEP’s Cold Climate Air Source Heat Pump Specification (NEEP, 2017 or more recent) and; – Have a COP at -15°C(5°F) greater than 2.0 at a max capacity operation and; – Maintain a max capacity at -15°C (5°F) that is greater than or equal to 55% of maximum capacity at 8.3°C (47°F) – For electrically heated homes only |
$1900.00 for one exterior unit and the first two interior units, plus $400.00 for each additional interior unit attached to the same exterior unit, up to a maximum participant incentive of $4000.00 |
|
Cold Climate Ducted ASHP |
– Must be 15 SEER or higher, 12.5 EER or higher and 8.5 HSPF or higher – Must meet NEEP’s Cold Climate Air Source Heat Pump Specification (NEEP, 2017 or more recent) – For electrically heated homes only |
$4000.00 |
|
Adaptive Thermostat |
-Must have heat pump lockout temperature control, which will be listed on eligible thermostat list approved by IESO (TBD) – For electrically heated homes only |
$50.00 |
For more information, please contact Sarah Coleman, Senior Project Coordinator, CDM at 866-483-0564.